• Users Online: 2736
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Ahead of print Browse Articles Search Archives Submit article Instructions Subscribe Contacts Login 
BRIEF COMMUNICATION
Year : 2018  |  Volume : 9  |  Issue : 1  |  Page : 60

Preliminary investigation of a novel mouthguard


Department of Restorative Dentistry, Schulich School of Medicine and Dentistry, Western University, London, Ontario N6A-3K7, Canada

Correspondence Address:
Les Kalman
Department of Restorative Dentistry, Schulich School of Medicine and Dentistry, Western University, 1151 Richmond Street, London, Ontario N6A-3K7
Canada
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ijpvm.IJPVM_376_17

Rights and Permissions

Background: Mouthguards (MGs) remain an important piece of personal protection for athletes for the prevention of injury. Although MGs provide tremendous benefits, the design and fabrication process does not record the position of the mandible or the occlusion, which could lead to injury. This study compared a novel MG to over-the-counter (OTC) and custom MGs on a skull model. Methods: The OTC MG was formed as per manufacturer's guidelines, the custom MG was laboratory fabricated, and the novel MG was fabricated through a proprietary process. Each group of the three MGs was assessed for vertical dimension change, occlusal contacts, and condylar displacement. Results: Average number of occlusal contacts for the OTC, custom and novel MG were 2.4, 4.0, and 10, respectively. There was a significant difference between all values (P < 0.05). Average change in vertical dimension for the OTC, custom, and novel MG were 15.3 mm, 9.3 mm, and 8.0 mm, respectively. The novel MG value was significantly different (P < 0.05). The average distance of condylar displacement for the OTC, custom and novel MG were 1.9 mm, 1.3 mm and 0.6 mm, respectively. Conclusions: The novel MG was significantly different (P < 0.05). The data from this preliminary investigation suggests that the novel mouthguard had maximized occlusal contacts, minimized vertical dimension change and condylar displacement as compared to OTC and custom MGs.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed3659    
    Printed104    
    Emailed0    
    PDF Downloaded314    
    Comments [Add]    
    Cited by others 4    

Recommend this journal